Enclosure management commands 114
• Description:
Enables Link Loss Failover for Onboard Administrator Redundancy.
• Access level/Bay level:
Operator, Administrator
• Restrictions:
You must have OA permission to perform this command
REMOVE LANGUAGE
• Command:
REMOVE LANGUAGE { <language> | <language code> }
• Description:
Removes the user specified language. <language> is the language name. <Language code> is a
two-letter designation for a language (EN—English, JA—Japanese, ZH—Chinese). To get a list of
installed language packs, use SHOW LANGUAGES command.
• Access level/Bay level:
OA administrator, OA operator
• Restriction:
None
RESTART OA
• Command:
RESTART OA [<bay number>]
• Description:
Resets the Onboard Administrator module specified by <bay number>. If no bay number is given, then
the Onboard Administrator the user is logged in to is restarted.
• Access level/Bay level:
OA administrator, OA operator
• Restrictions:
None
SET DATE
• Command:
SET DATE MMDDhhmm [[CC]YY][TZ]
• Description:
Sets the date of the enclosure with the following definitions:
o MM: Month
o DD: Day