General management commands 55
SET FACTORY
Command:
SET FACTORY
Description:
o Restores the Onboard Administrator to its factory defaults. The Administrator account password
does not change.
o The Onboard Administrator restarts after all changes are made.
o All existing settings are lost when this operation is run.
IMPORTANT: Before resetting factory defaults, save your configuration. To upload a script
containing your current configuration, use the UPLOAD CONFIG (on page 139) command. You
can use this script later to restore settings that are lost after a factory reset.
NOTE: After a factory reset, the enclosure IPv6 network settings (IPv6, SLAAC, and DHCPv6) are
enabled by default.
Access level/Bay level:
OA administrator
Restrictions:
You cannot run SET FACTORY in FIPS Mode ON/DEBUG.
SET SCRIPT MODE
Command:
SET SCRIPT [MODE] {ON | OFF}
Description:
o This command ceases all prompting and verifying of entries when SCRIPT MODE is on.
o The ADD USER command must have a password argument if executed in SCRIPT MODE.
o Default values are used for any parameters that would normally require user interaction.
o This setting is only effective for the current CLI session.