A SERVICE OF

logo

Interconnect management commands 171
Restrictions:
You must have access to the specified bay number.
SET INTERCONNECT POWERDELAY
Command:
SET INTERCONNECT POWERDELAY {ALL | <bay number> [{ - | , } <bay number>]}
{number of seconds to delay power | NOPOWERON}
Description:
Sets the PowerDelay status for the specified interconnect or range of interconnects. If the delay is zero,
the delay has no effect on the device. If the delay is NOPOWERON, the device cannot power on until
all devices have completed their delays.
Access level/Bay level:
Administrator
Bay specific
Restrictions:
You must have access to the specified bay number.
SET INTERCONNECT UID
Command:
SET INTERCONNECT UID {ALL | <bay number> [{ , | - } <bay number>]} {ON | OFF}
Description:
Turns an interconnect UID on or off
Access level/Bay level:
All
Bay specific
Restrictions:
You must have explicit access to a bay given by the ASSIGN INTERCONNECT command.
SHOW INTERCONNECT
Command:
SHOW INTERCONNECT {INFO | LIST [IPV6] | PORT MAP | POWERDELAY | SESSIONS |
STATUS} [ALL | <bay number> | <bay number>-<bay number>]
Description:
o Displays the following information, depending on the keyword specified:
Interconnect type
IPv4 information
IPv6 information
Manufacturer name