Enclosure management commands 116
The <asset tag> must be 0 to 32 characters long and includes all alphanumeric, underscore (_), and
dash (-) characters.
SET ENCLOSURE NAME
• Command:
SET ENCLOSURE NAME "<enclosure name>"
• Description:
o Changes the enclosure name
o The default enclosure name is the mid-plane serial number
• Access level/Bay level:
OA administrator, OA operator
• Restrictions:
The <enclosure name> must be 1 to 32 characters long and includes all alphanumeric, underscore (_),
and dash (-) characters.
SET ENCLOSURE PART_ NUMBER
• Command:
SET ENCLOSURE PART_NUMBER "<part number>"
• Description:
Sets the part number of the enclosure
• Access level/Bay level:
OA administrator
• Restrictions:
Must be 10 characters in length and the first character must be a digit. Acceptable characters are all
alphanumeric and the dash (-).
SET ENCLOSURE PDU_TYPE
• Command:
SET ENCLOSURE PDU_TYPE {1|2|3|4|5}
• Description:
Sets the enclosure PDU type to:
o 1=Single-phase
o 2=Three-phase
o 3=Three-phase, international
o 4=DC Power Input Module
o 5=Single phase IPD
• Access level/Bay level: