HP Insight Remote Support commands 198
Remote Support must be enabled before sending a data collection. If the enclosure contains a large
number of blades, the test might take several minutes. After the test is complete, the status is reflected in
the SHOW REMOTE_SUPPORT command output.
SET REMOTE_SUPPORT DIRECT
ONLINE_REGISTRATION_COMPLETE
• Command:
• SET REMOTE_SUPPORT DIRECT ONLINE_REGISTRATION_COMPLETE
• Description:
Upon entering this command, you are asked to confirm that you registered at the HP Insight Online
website (http://www.hp.com/go/insightonline.). This is the second of two steps to finish registering for
Insight Remote Support through a direct connection to HP Insight Online. To confirm that you have
completed this step, answer YES.
To send a test event to confirm the connection between OA and Insight Remote Support, use the TEST
REMOTE_SUPPORT (on page 200) command.
• Access level/Bay level:
OA administrator
• Restrictions
If your enclosure uses a web proxy server to access the Internet, enter proxy information with the SET
REMOTE_SUPPORT DIRECT PROXY (on page 198) command. Proxy settings must be kept up to date
to enable your c-Class enclosure to continue to send remote support data to HP.
SET REMOTE_SUPPORT DIRECT PROXY
• Command:
SET REMOTE_SUPPORT DIRECT PROXY {NONE | "<proxy server>" <proxy port>
["<proxy username>"] ["<proxy password>"]}
• Description:
Sets Remote Support proxy settings required if the Onboard Administrator enclosure uses a proxy server
to access the Internet.
• Access level/Bay level:
OA administrator
• Restrictions
Proxy settings must be kept up to date to enable your c-Class enclosure to continue to send remote
support data to HP.
SHOW REMOTE_SUPPORT
• Command:
SHOW REMOTE_SUPPORT
• Description: