61200510L1-35E Copyright © 2005 ADTRAN 190
show garp timer
Use the show garp timer command to see the current configured Generic Attribute Registration Protocol
(GARP) application timer values.
Syntax Description
No subcommands.
Default Values
No default value necessary for this command.
Applicable Platforms
This command applies to the NetVanta 300, 1000, and 1000R Series units.
Command History
Release 8.1 Command was introduced.
Usage Examples
The following example displays the current configured GARP application timer values:
>enable
#show garp timer
Timer Timer Value (milliseconds)
-------- --------------------------
Join 200
Leave 600
LeaveAll 10000