
by the upgrade procedure. Note that you can run this procedure manually to configure or
reconfigure your system as a member of an OpenVMS Cluster. For more information about
configuring a member of an OpenVMS Cluster, see the Guidelines for OpenVMS Cluster
Configurations manual.
6.3.11 Setting OpenVMS Galaxy Information (Alpha Only)
The procedure next asks whether your system is an instance in an OpenVMS Galaxy. The display
is similar to the following:
Will this system be an instance in an OpenVMS Galaxy? (Yes/No)
If you answer YES to this question, and you also answered YES to the OpenVMS Cluster question,
then information about required remedial kits is displayed. Your answer to this question
determines how the system parameter GALAXY is set.
6.3.12 Updating Time Zone Information
For local time zone support to work correctly, the time zone that accurately describes the location
you want to be considered as your default time zone must be set. In addition, your system must
be configured correctly to use a valid OpenVMS time differential factor (TDF).
If the installation procedure determines that time zone information is incomplete, it prompts
you to set the correct default time zone and TDF for your system. For information about setting
the time zone information, see Section 3.4.3 (page 55).
For more information about TDF and local time zone support, see the HP OpenVMS System
Manager's Manual, Volume 1: Essentials.
6.3.13 Upgrading Windowing, Networking, and Related Products
The procedure now presents information about the optional DECwindows GUI (DECwindows
Motif for OpenVMS), and networking (DECnet and TCP/IP) products that will be upgraded
along with the OpenVMS operating system. As noted by the procedure, you can change the
default values for these products later in the installation procedure.
NOTE: The following display shows what you might see during an OpenVMS Integrity servers
installation. Some of the products listed are supported on OpenVMS Integrity server systems
only.
The following products are part of the OpenVMS installation;
if necessary they will be installed or upgraded along with the OpenVMS operating system:
o Availability Manager (base) for OpenVMS I64
o CDSA for OpenVMS I64
o KERBEROS for OpenVMS I64
o SSL for OpenVMS I64
o Performance Data Collector (base) for OpenVMS I64
o HP Binary Checker for OpenVMS I64
o WBEM Services for OpenVMS (WBEMCIM)
o WBEM Providers for OpenVMS (WBEMPROVIDERS)
If necessary, the following optional products will also be upgraded
along with the OpenVMS operating system:
o DECwindows Motif for OpenVMS I64
o DECnet-Plus for OpenVMS I64
o DECnet Phase IV for OpenVMS I64
o HP TCP/IP Services for OpenVMS
If you want to add or delete optional products, you can do so later
in the upgrade by answering NO to the following question:
"Do you want the defaults for all product options?"
Availability Manager (base) for OpenVMS I64
is already installed on your system. An upgrade is not required.
CDSA for OpenVMS I64 ...
6.3 Performing the Upgrade 115