<Inputs/Outputs>
*0 dBu - 0.775 Vrms, 0 dBV = 1 Vrms.
Reference level : -12 dB/-18 dB/-20 dB (default: -18 dB, selectable from
the "Reference Level?" menu in the Setup mode)
Nominal input level : +4 dBu/-10 dBV (balanced), selectable using the input
level select switch on the rear panel
ANALOG INPUTs (TR 1 through TR 4)
• Connector : XLR-3-31 type (balanced, pin 2: hot)
• Input impedance : 10k or more
• Nominal input level : +4 dBu
• Maximum input level : +24 dBu
ANALOG OUTPUTs (TR 1 through TR 4)
• Connector : XLR-3-32 type (balanced, pin 2: hot)
• Applicable load impedance : 600 or more
• Nominal output level : +4 dBu
• Maximum output level : +24 dBu
Monitor OUTPUTs (TR 1 through TR 4)
• Connector : 1/4" phone jack (unbalanced)
• Applicable load impedance : 10k or more
• Nominal output level : -10 dBV
• Maximum output level : +10 dBV
PHONES output
• Connector : 1/4" phone jack
• Applicable load impedance : 8 or more
• Maximum output level : 100 mW (into 32 ohms)
* Monitor track(s) selectable using the [PHONES] switches on the front panel.
DIGITAL INPUTs (TR 1-2, TR 3-4)
• Connector : XLR-3-31 type
• Format : IEC 60958 (S/PDIF) or IEC 60958 (AES/EBU),
automatically detected
DIGITAL OUTPUTs (TR 1-2, TR 3-4)
• Connector : XLR-3-32 type
• Format : IEC 60958 (S/PDIF) or IEC 60958 (AES/EBU), selectable
by the "D. OUT?" menu in the Setup mode
* When dealing with a digital signal at 176.4 kHz or 192 kHz sampling rate, channels L
and R are assigned to TR 1-2 and TR 3-4 respectively.
GPI IN/OUT
• Connector : DIN 5-pin
* ON or OFF selectable by the "GPI?" setting menu in the Setup mode.
GPI IN
Pin 1: GND
Pin 2: STOP
The "low" pulse activates the function equivalent to the [STOP] key.
Pin 3: PLAY
The "low" pulse activates the function equivalent to the [PLAY] key.
Pin 4: >>
The "low" pulse activates the function equivalent to the [>>|] key.
Specifications